CTI 8300 Compressor with 8004 Controller
$4,100 $3,000
CTI 8303 Compressor. This is a series 8300 Compressor and can be outfitted to match the specifications of most 8300 series models. Call us for your specific needs. Unit can optionally be configured with either an 8001 or and 8004 Controller for an additional cost.
Image is not of the exact unit for sale, but represents the unit that will be sold.
Rebuilt Brooks CTI-Cryogenics 8300 Helium Compressor
OEM Part Numbers this unit can be configured to meet:
8052005 water cooled
Refurbished and ready to go! Call us for details and Warranty Information.
We also can reconfigure this compressor to accommodate an 8001 or 8004 controller at an additional cost. Call us for more details.
Condition (eBay) | Seller refurbished (reconfigurable) |
---|---|
Item Location | US |
Zip Code (Item Location) | 95112 |
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Only logged in customers who have purchased this product may leave a review.
Write a review- 8100
- Adixen
- Anest Iwata
- Axcelis
- Chiller
- compressor
- Consulting
- Cooling
- cryo
- cryogenic
- cryopump
- CTI
- dry
- Dry Pump
- Dry Scroll
- E2M40
- E2M80
- Edwards
- granville-phillips
- GVSP30
- Leybold
- M40
- M80
- M and W
- MFC
- MKS
- NT20
- NT20 Interface Cable to Turbo
- OB 8
- On board
- Pfeiffer
- PTS 300
- PTS 600
- pump
- Residual Gas Analyzer
- RGA200
- sensor
- SRS
- Stanford Research Systems
- surplus
- Turbo
- Unit
- vacuum
- Vacuum Pump
- Varian
Related Products
• air-cooled, oil-free scroll-type vacuum
• low noise & vibration
• compact design
• no lubricant maintenance or sealing water administration
• free from installation restrictions
• low power consumption
1 in stock
• air-cooled, oil-free scroll-type vacuum
• low noise & vibration
• compact design
• no lubricant maintenance or sealing water administration
• free from installation restrictions
• low power consumption
1 in stock
1 in stock
1 in stock
The 200 amu residual gas analyzers from SRS offer exceptional performance and value. These RGA’s provide detailed gas analysis of vacuum systems at about half the price of competitive models. Each RGA system comes complete with a quadrupole probe, electronics control unit (ECU), and a real-time Windows software package that is used for data acquisition and analysis, as well as probe control.
Specifications
Operational
Mass Range: | |
RGA200 | 1 to 200 amu |
Mass filter type | Quadrupole
(Cylindrical rods, rod diameter: 0.25”, rod length: 4.5”) |
Detector type | Faraday cup (FC) – standard
Electron multiplier (CDEM) – optional |
Resolution
(per AVS standard 2.3). |
Better than 0.5 amu @ 10% peak height
Adjustable to constant peak width throughout the entire mass range. |
Sensitivity (A/Torr)* | 2.10-4 (FC)
<200 (CDEM). User adjustable throughout high voltage range. |
Minimum detectable
partial pressure (MDPP)* |
5.10-11 Torr (FC).
5.10-14 Torr (CDEM). |
Operating pressure range | 10-4 Torr to UHV (FC)
10-6 Torr to UHV (CDEM) |
Max. bakeout temperature (without
ECU) |
300qC |
Operating Temperature | 70qC (max.) |
Recommended bakeout temperature | 200°C (O100HJR Heater Jacket recommended) |
Total press.
measurement |
Available with FC measurements only |
* Measured with N2 @ 28 amu with 1 amu full peak width @ 10% height, 70 eV electron energy, 12 eV ion energy and 1 mA electron emission current. Ionizer
Design | Open ion source, cylindrical symmetry. |
Operation | Electron impact ionization. |
Material | Stainless steel, type 304. |
Filament | Thoriated Iridium (dual) with firmware protection. Field |
1 in stock
4 in stock
Reviews