MKS 1179B00734CR14V Mass Flow Controller 30,000sccm/H2 with Cert
$475
Item is in used condition with original packaging and calibration sheet. Unit is sold As-is in working condition.
Unit is Configured for H2 (Hydrogen) and the flow rate is 30,000 sccm. Includes a calibration certificate for each unit.
We have multiple units in stock. Ready to ship
Images are of several units we have in stock. Actual unit shipped may or may not be included with the pictures.
Condition (eBay) | Used |
---|---|
Item Location | US |
Zip Code (Item Location) | 95112 |
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Only logged in customers who have purchased this product may leave a review.
Write a review- 8100
- Adixen
- Anest Iwata
- Axcelis
- Chiller
- compressor
- Consulting
- Cooling
- cryo
- cryogenic
- cryopump
- CTI
- dry
- Dry Pump
- Dry Scroll
- E2M40
- E2M80
- Edwards
- granville-phillips
- GVSP30
- Leybold
- M40
- M80
- M and W
- MFC
- MKS
- NT20
- NT20 Interface Cable to Turbo
- OB 8
- On board
- Pfeiffer
- PTS 300
- PTS 600
- pump
- Residual Gas Analyzer
- RGA200
- sensor
- SRS
- Stanford Research Systems
- surplus
- Turbo
- Unit
- vacuum
- Vacuum Pump
- Varian
Related Products
The 200 amu residual gas analyzers from SRS offer exceptional performance and value. These RGA’s provide detailed gas analysis of vacuum systems at about half the price of competitive models. Each RGA system comes complete with a quadrupole probe, electronics control unit (ECU), and a real-time Windows software package that is used for data acquisition and analysis, as well as probe control.
Specifications
Operational
Mass Range: | |
RGA200 | 1 to 200 amu |
Mass filter type | Quadrupole
(Cylindrical rods, rod diameter: 0.25”, rod length: 4.5”) |
Detector type | Faraday cup (FC) – standard
Electron multiplier (CDEM) – optional |
Resolution
(per AVS standard 2.3). |
Better than 0.5 amu @ 10% peak height
Adjustable to constant peak width throughout the entire mass range. |
Sensitivity (A/Torr)* | 2.10-4 (FC)
<200 (CDEM). User adjustable throughout high voltage range. |
Minimum detectable
partial pressure (MDPP)* |
5.10-11 Torr (FC).
5.10-14 Torr (CDEM). |
Operating pressure range | 10-4 Torr to UHV (FC)
10-6 Torr to UHV (CDEM) |
Max. bakeout temperature (without
ECU) |
300qC |
Operating Temperature | 70qC (max.) |
Recommended bakeout temperature | 200°C (O100HJR Heater Jacket recommended) |
Total press.
measurement |
Available with FC measurements only |
* Measured with N2 @ 28 amu with 1 amu full peak width @ 10% height, 70 eV electron energy, 12 eV ion energy and 1 mA electron emission current. Ionizer
Design | Open ion source, cylindrical symmetry. |
Operation | Electron impact ionization. |
Material | Stainless steel, type 304. |
Filament | Thoriated Iridium (dual) with firmware protection. Field |
1 in stock
• air-cooled, oil-free scroll-type vacuum
• low noise & vibration
• compact design
• no lubricant maintenance or sealing water administration
• free from installation restrictions
• low power consumption
1 in stock
• air-cooled, oil-free scroll-type vacuum
• low noise & vibration
• compact design
• no lubricant maintenance or sealing water administration
• free from installation restrictions
• low power consumption
1 in stock
Brooks CTI-Cryogenics 9600 Helium Compressor - REBUILT by HVS! Reconfigurable to these Manufacturer OEM Numbers: 8135900G001 low voltage 8135908G001 low voltage
1 in stock
MKS Sensor Model number 750B12TCB26C
Item is in used, but excellent condition.
Call us for additional details
15 in stock
4 in stock